Contact our technical sales
team now to discuss your
requirement

+44 (0) 845 9000 601
info@omni.uk.com
Click here to order your Omni Instruments 2010 Calendar           
Request a quote
click here to send us your inquiry for our immediate attention
 
Basket My Account
Home About Us Employment Applications Sitemap  
 
Data Loggers - Temp / RH Acceleration & Pressure
Data Loggers - Industrial General Purpose
Data Acquisition Systems High Speed & PC
Displacement Sensors
Display & Control Products Signal Amplifiers
Flow Meters
Gas Detection Equipment
Gyros & Accelerometers IMU's & Tilt Sensors
Hire Equipment
Level & Distance Sensors
Load & Torque Sensors
Pressure Sensors
Radio & GSM Telemetry
Recorders - Chart
Serial & Ethernet Communications
Solar & Wind Power Batteries & Enclosures
Temperature and Humidity
Test & Calibration
Vibration Monitoring
Voltage & Current Sensors Energy Monitoring Systems
Water Quality Sensors Subsea & Offshore Systems
Weather Stations and Instruments
Omni Application Examples
 

 

Load & Torque Sensors \ Load Cell Instrumentation \ Programmable Load Cell Amplifier

 

«« previous product   5 / 8   next product »»

Programmable Load Cell Amplifier

The 2261 is a programamble load cell amplifier suitable for 4 wire bridge / strain gauge sensors. Both zero and span are programmable via the front key pad and the LED display allows easy setup.The unit also has NPN/PNP input for external taring and a regulated supply for standard transducers
 
 
 
 

2-3 Days Del.

 
 
Downloads

Send page to a colleague

 

 
 

Product details

 
Common specifications:
Supply voltage.................................…24 VDC ±20%
Internal consumption ......................… 2.2 W
Max. consumption.............................. 7.2 W
Signal/noise ratio................................ Min. 60 dB
Signal dynamics, input ....................... 17 bit
Signal dynamics, output............... ...... 16 bit
Updating time..................................... 20 ms
Response time, programmable ........ ... 0.06...999 s
Calibration temperature.................. .... 20...28°C
Temperature coefficient..................  ... < ±0.01% of span / °C
Linearity error .................................... ≤±0.1% of span
Effect of supply voltage change..........   < ±0.002% of span/ %V
Auxiliary voltage:
Transducer supply.............................. 5...13 VDC
Load (max)........................................ 230 mA
EMC-Immunity influence............... ..... < ±0.5% of span
Humidity .................................. ........ < 95% RH (non-cond.)
Dimensions (HxWxD).......................... 80.5 x 35.5 x 84.5 mm
Tightness...................................  ...... IP50
Weight ............................................. 130 g


Electrical specifications - Input:
mV-input:
Measurement range ........................... -40...100 mV
Min. measurement range (span).......  .. 10 mV
Max. offset......................................... 70% of selec. max. value
Input in relation to supply gnd.........   ... > - 5 V and < +10 V
Max. cable resistance per wire.......  .... 15 Ω
Suppression of
transducer cable resistance ............... > 300
Input resistance................................. > 10 ΜΩ
Overrange.......................................... 0...999% of selected measurement range
Digital input:
NPN.................................................. Pull up 24 VDC / 6.9 mA
PNP ................................................. Pull down 0 VDC/6.9 mA
Trig level low...................................... < 6 VDC
Trig level high..................................... > 10.5 VDC
Pulse width........................................ > 30 ms

Electrical specifications - Output:

Current output:
Signal range ...................................... 0...20 mA
Min. signal range (span) ..................... 5 mA
Max. offset......................................... 50% of selec. max. value
Load (max.)................................. ...... 20 mA / 600 Ω./ 12 VDC
Load stability ..................................... < ±0.01% of span/100 .
Current limit........................................ < 23 mA
Voltage output through internal shunt:
Signal range ....................................... 0...10 VDC
Min. signal range (span) ................. .... 250 mVDC
Max. offset.......................................... 50% of selec. max. value
Load (min.).......................................... 500 kΩ
Voltage limit ....................................... < 11.5 VDC
Observed authority requirements: Standard
EMC 89/336/EEC, Emission ......   ....... EN 50 081-1, EN 50 081-2
Immunity............................................. EN 50 082-2, EN 50 082-1
 

Components / Downloads

 
For further information, technical advice, or a quotation please call or email us. If you are not sure which product you need one of our technical sales advisors will be happy to discuss your application. We also accept company purchase orders by fax or post. Credit card orders can also be placed over the phone for any product.
 

ref

description

downloads

price (£)

Order Item

2261

Programmable mv / load cell amplifier, power supply 24vDC

 

Data Sheet

 